Certification in LPG Measuring Systems: ATEX, MID and OIML R117

Certification in LPG Measuring Systems: ATEX, MID and OIML R117
SHARE NEWS
Added Date : 20 11 2026

When a station investor compares two LPG dispensers, the first differences that get discussed are price, housing material and delivery time. The differences that decide whether the equipment can legally sell product are written on the certificate plate. This guide explains the certification framework behind an LPG measuring system and what a buyer should ask for before signing.

Three different questions, three different certificates

Certification of forecourt equipment answers three separate questions, and they are often mixed together:

  • Is it safe in an explosive atmosphere? This is the ATEX question.
  • Does it measure correctly for trade? This is the MID and OIML question.
  • Is this individual unit still accurate today? This is the verification and calibration question.

A dispenser can be excellent on one of these and unacceptable on another. All three have to be satisfied at the same time for a station to sell legally.

ATEX: equipment for an explosive atmosphere

An LPG forecourt is a classified area. Equipment installed there must be designed so that it cannot become an ignition source under normal operation or foreseeable fault conditions. In the European framework this is covered by Directive 2014/34/EU, usually referred to as ATEX, and LPG dispensers are required to carry this certification together with the certificates required by the LPG regulations.

ATEX is not limited to the cabinet. It extends to the components inside and around it: solenoid valves, wiring, and the cable glands that carry cables through the housing. Using ex proof certified metal cable glands in the dispenser is a detail that is easy to overlook in a quotation and important for the safety of the installation. The same logic applies to electric motors used in the station environment, which is why explosion proof motors form their own product family.

MID and OIML R117: measuring for trade

A device that sells product by volume is a legal measuring instrument. In the European system, measuring systems for the continuous dynamic measurement of liquids other than water fall under Annex MI-005 of the Measuring Instruments Directive. In practice this is visible on the equipment as module certificates, for example in the form of type examination and conformity declarations quoted on the dispenser documentation.

Alongside the directive sits OIML R117, the international recommendation for dynamic measuring systems for liquids. The meter inside an LPG dispenser must hold OIML R117 certification. A typical four piston prima meter built for this duty has a measurement accuracy of 0.5 per cent, operates with an improved magnetic system and is designed so that parts can be replaced individually rather than as a complete assembly.

For the buyer the practical consequence is simple: ask for the certificate numbers of the meter and of the measuring system, not only for a general statement that the product is certified.

Hoses, nozzles and the rest of the chain

Certification does not stop at the cabinet door. The hose that carries liquid LPG to the vehicle must comply with EN 1762. It has to resist LPG pressure, must not deteriorate on a liquid or vapour basis, and must contain a conductive wire or weave so that static electricity generated during filling can be discharged safely. At the end of the hose, the filling nozzle is selected according to the market and the application: an Italian type T3 nozzle, an acme type nozzle, or a cylinder filling nozzle in bottling plants.

These components are consumables in daily use and certified parts in regulatory terms. Replacing them with unmarked equivalents during maintenance quietly removes the station from compliance.

Verification: certification is not a one time event

A certificate describes the design. It does not promise that the instrument in front of you is still accurate after two years of service. That is the role of periodic verification, performed with a reference instrument.

The reference device used for LPG is the master meter. Two types are in common use: a prima meter based reference, and a mass flow reference working on the Coriolis principle. The prima meter type has a measurement accuracy of 0.6 per cent within the legal framework, while its actual figure is between 0.3 and 0.4 per cent; the declared accuracy of the Coriolis based mass flow type is a maximum of 0.2 per cent.

Two intervals matter in practice. The measurement accuracy of dispensers should be checked twice a year within the standard service period. The master meter used for those checks should itself be calibrated once a year by an accredited organisation, otherwise the reference loses its meaning.

Seals: the quiet part of the system

In a legal measuring system, seals are what connect the certificate to the instrument. The calibration adjustment section of the meter is sealed, and so are the temperature compensation probe and its connection to the electronic unit. Any intervention that breaks a seal requires the system to be verified again before it returns to service.

This is also why adjustment work has a defined procedure rather than being a free hand operation. On a prima meter the seal is removed, the adjustment cover is opened, the starting point is marked on the drum, and the correction is made by turning the drum within the known adjustment capacity of the device before the pin is replaced and the system is sealed again.

A short checklist before purchase

  • ATEX certification for the dispenser and for the components inside it, including cable glands.
  • OIML R117 certificate for the meter, and the measuring system certificates on the documentation.
  • Hose compliance with EN 1762 and the correct nozzle type for the application.
  • A declared accuracy figure for the meter, not only a general claim of accuracy.
  • A verification plan: who performs the twice yearly check, with which master meter, and where that master meter is calibrated.
  • Availability of certified spare parts and a service network that can reach the station.

2A Engineering supplies LPG and CNG dispensers, master meters, pumps, tanks and the remaining station equipment as a complete chain, so that certification, verification and spare part supply are handled by the same supplier.

Keeping the documents and preparing for inspection

Certificates are requested not only at the purchase stage but throughout the operating life of the station. They therefore belong in one file rather than scattered across folders. The file should hold the dispenser and meter certificates, the ATEX certificates, the conformity documents for hoses and nozzles, the calibration certificate of the master meter, the periodic verification records, and the dates and results of any adjustments made.

A practical suggestion is to keep that file both on paper and digitally. The digital copy makes it easy to share with the service team and with an inspector, while the printed copy stays accessible at the station. If the validity dates are entered in a calendar, problems such as a verification performed with an out of calibration master meter, and therefore invalid, do not arise.

The same discipline applies to spare part replacements. When a hose, a nozzle or a filter is changed, the document for the part used should be added to the file, and uncertified equivalents should not be used. If a change touches the measuring system, the system has to be verified again.

Frequently asked questions

What certificates must an LPG dispenser carry?

ATEX certification under Directive 2014/34/EU as required by the LPG regulations, together with the measuring system certificates covering the meter, which must hold OIML R117 certification.

What is the difference between certification and verification?

Certification describes the approved design of the equipment. Verification checks whether a specific installed unit still measures within the legal limits, and is repeated at intervals.

How accurate is the meter in an LPG dispenser?

A four piston prima meter built for this duty has a measurement accuracy of 0.5 per cent and holds OIML R117 certification.

Which master meter type is more accurate?

The mass flow type working on the Coriolis principle declares a maximum deviation of 0.2 per cent, while the prima meter type works to 0.6 per cent within the legal framework with an actual figure between 0.3 and 0.4 per cent.

What happens if a seal is broken during maintenance?

The measuring system must be verified again before returning to service. Seals on the meter adjustment section and on the temperature compensation probe are part of the legal chain.